11kv 12kv SCB10 3 phase 500kva 630kva 1500kva dry type transformer
Certificate: ISO9001; Voltage Level: 10KV; connection style: Yyn0/Dyn11; Standard: IEC60076;
Good Quality 10-35kv SCB10 series of dry-type transformers
Usage: Power; Phase: Three; Coil Structure: Toroidal; Coil Number: Autotransformer;
KBSG-800/6 Series flameproof explosion dry type transformer
load:4500W; no-load current:1.0%; short-circuit resistance:4%; outline dimension:2740X990X1560;
KBSG-160/10 mine-used flameproof explosion dry type transformer
no-load current:2.0%; short-circuit resistance:4%; outline dimension:2500X850X1300;
KBSGZY-100/6 mine-used flameproof explosion mobile substation
KBSGZY mine-used flameproof mobile substation is an electrical equipment for a change in the coal mine,composed of dry-type transformer which used for mobile substaion, high voltage power distribution switch used for mobile substation and flameproof low voltage protection box three parts.
Good price house estate used epoxy resin casting dry-type transformer
no-load loss: 3320 W; load loss 120C: 17170 W; impedance voltage: 6.0; noise level: 60;
SG(B)10, SG(B)11 series non encapsulated dry type transformer
The high voltage coils use Nomex-410 insulating material, the VPI vacuum pressure impregmating international advanced equipment solventless insulation paint, sealing with high strength grade H insulation materials, and high temperature curing, ensure no partial discharge under operation condition.
THREE PHASE AND POWER USAGE CAST RESIN TRANSFORMER
HIGH VOLTAGE COILS ARE WRAPPED WITH POLYESTER ENAMELED WIRES,FILLED WITH GLASS FIBER, AND THEN RESIN UBDER VACUUM CONDITION. IT BECOMES SOILD UNDER HIGH TEMPERATURE.IT IS WITH HIGH MECHANICAL INTENSITY,LOW VOLTAGE COILS ARE WRAPPED WITH A WHOLE PRICE OF COPPER FOIL,WITH STRONG ANTISHORTCUT CAPACITY.
SG(B)10 Non-encapsulated Coil Three-phase Dry Type Transformer
The non-encapsulated coil three-phase dry type power transformer that adopt UL certificated NOMEX insulation system, with advantages of safe, reliable, energy saving, fireproof , explosion resistant, simple maintaining and so on.
SCB10 Series High Quality Two Cooling Modes Dry Type Transformer
When the highest ambient temperature is +40℃, if it is natural air cooling (AN), the transformer can output 100% of rated capacity continuously.
SCB10 cast resin dry type toroidal power distribution transformer
As high-tech product that promoted by the country, the product has many advantages such as high efficiency, low loss. Its social benefits are remarkable that it will save much of electricity consumption and operating cost.
Indoor Epoxy resin cast three phase dry type power transformer
Winding: Aluminium; Frequency: 50/60Hz; Vector group: Dyn11 / Yyn0; Impedance voltage: 6%;
SCBH New Style Low Losses For Business Centers Cast Resin Transformer
Temperature rise: less than or equal to 40 degrees Celsius; Norminal Frequency: 50HZ/60HZ; Altitude for product use: less than or equal to 1000m; Color: Optional;
SGB 10 35/0.4 KV 630~3150kVA Resin-insulated Dry-type Transformer
It is safe, non-pollute, and flame proof which can be installed directly on the load centre with the merits of free maintenance, easy installation, low combined operation cost, low loss and excellent humidity resistance.
high voltage insulation no-encapsulated-winding distribution transformer
Coil Number: Autotransformer; Frequency: 50/60HZ; Rated voltage: 10kV-35kV; Rated capacity: 100-2500kva;
SGB10 Series type 10kv to 0.4kv step down distribution transformer
Coil Number: Autotransformer; certificate: CQC,CCC; Cooling method: ONAN; Rated capacity: 30KVA-2500KVA;
SCB10 three phase dry type step down distribution transformer
Material: Copper Winding; Frequency: 50/60Hz; Impedance Voltage (%): 4%, 4.5%; High voltage tapping rang: ±5% or ±2x2.5%;
SC(B)10 Three Phase Dry Type Power distribution transformer
A unique ceramic type of insulation structure is adopted in H-class high strength insulation cylinders and high-frequency ceramic cushion blocks are adopted to ensure that no deformation will occur.
SCB(10) 10kv Three Phase Grounding Dry type transformer
It is suitable for airport, station, wharf, the subway, power plant, substation, hospital, hotel, business center, sports venue, high-rise building, residential area and industrial and mining enterprise etc.
SCB9/SCB10 three phase 11KV cast resin dry type transformer
This series Dry Type Transformer Price having adopted the corrugated tank structure. It is a fully sealed, fully oiled, double windings, and no excited distribution transformer.
3 phase 100kva amorphous alloy distribution power transformer
-Low off-load losses: Amorphous alloy core type core type transformer would save 65% off-load losses compared to traditional transformer.
SCB 100kva 110kv dry type toroidal power distribution transformer
Reliability: Using C grade insulation level and low partial discharge and long service life. Environment : energy saving, recyclable,no pollution in the process of transportation,, storage,operation.
Low off-load losses three phase Amorphous Alloy Dry Type Transformer
-Low off-load losses: Amorphous alloy core type core type transformer would save 65% off-load losses compared to traditional transformer.
2500kVA Low Frequency Dry-Type Distribution Transformer
Application: Power, Electronic; Core: Core-type Transformer; Winding Type: Two-winding Transformer; Usage: Power Transformer;
ISO9001 10kv-35kv Low Noise Dry Type Power Transformer
Casted by epoxy resin, 18 ~ 22kV/mm insulation breakdown field, the insulation class is F, the maximum allowable temperature is 155 deg c, the winding temperature rise limit is 100K.
IEC60076 Standard 10KV Toroidal Dry type transformer
Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . The core is made of high-permeable grain-orientated silicon sheet and cast with imported epoxy resin. Thanks to advanced technology, quality raw materials , scientific management, and perfect inspection means.
SCB10 Series 30-3000kva 220v 12v dry type power transformer
Name: S11-250 KVA oil-immersed power transformer; Standard: IEC60076; Rated capacity: 30-3000kva; Rated voltage: 250KVA;
Dg and Sg Series A GRADE Three Phase Electric Dry Type Transformer
1.Input voltage:rated voltage ±10%; 2.Output voltage:rated voltage +3%(no load); 3.Efficiency:≥95%; 4.Waveform distortion:no additional waveform distortion.
SG Series Separated Winding Core-type Dry Type Transformer
DG and SG series single-phase and three-phase dry type transformer adopts high quality material and advanced technology,it has advantages of damp-proof and convenient maintenance.
33kv 630kVA High Frequency Substation Dry Type Transformer
Capacity: 30~3500kVA; Voltage grade: 6~35kV; Tapping range: ± 2× 2.5% or others; Number of phases: Three-phase or single phase.
ISO9001 Power Frequency Multi-winding Dry Type Transformer
Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . The core is made of high-permeable grain-orientated silicon sheet and cast with imported epoxy resin. 1. Model No: SCB11 outdoor transformer; 2. Phase: 3phases.
ISO9001 500kVA Voltage Power Frequency Dry Type Transformer
Our transformers sell well all over the world. We have won a good reputation among customers at home and abroad. We will do our best to provide more high-quality products and services for you in the future! 1. Model No: SCB11 outdoor transformer; 2. Phase: 3phases.
SCB-1250/10 Series H Class Three Phase Dry-Type Transformer
Dry transformer is mainly applied to heating furnace such as glass furnace, electric resistance furnace, vacuum furnace, polycrystalline furnace etc and electroplate, traction rectifier transformer for first grade.
SCB9 Series 11kv Cast Resin Two-winding Dry Type Transformer
Cast resin dry type transformer is a safe, non-pollute, and flame proof product, which can be installed directly on the load center with the merits of free maintenance, easy installation, low operation cost, low loss and excellent humidity resistance.
500V Sg-500 500va 50-60Hz Three Phase Dry-Type Transformer
SG series dry-type indoor transformer, in natural cooling, it's suitable in AC50~60Hz, input voltage not exceed 500V circuit. as the local illumination power source of machine tools & other devices.
PEOPLE SC(B)10 SCR10 Resin Casting Dry Type Power Transformer
SC(B9), SCR9, SC(B)10, SCR10 Resin casting dry type power transformer produced by our company is a new generetion of product with low loss and noise. Product complies with standards: IEC726, GB6450 and GB/T10228-1997S. Phase: Three; Certification: CCC; Brand: People.
SCB10 50Hz Impregnated Two-winding Dry Type Power Transformer
Please specify the product model, rated capacity, HV/LV rated voltage and high-voltage tapping range, phase number, frequency, connection group symbol and so on in the order. Trademark: CNHK; Specification: COPPER; HS Code: 8504220000.
SCB10 50Hz Epoxy Resin Two-winding Dry Type Power Transformer
Please specify the product model, rated capacity, HV/LV rated voltage and high-voltage tapping range, phase number, frequency, connection group symbol and so on in the order. Shape of Core: Ring; Trademark: CNHK; Specification: COPPER.
SCB Cast Resin Three Phase Distribution Dry Type Transformer
Low loss, compact and light weight, low noise level,clamp-proof,anti-fouling,high mechanical strength, flame resisting, strong overload ability and low partial discharge quality,they are application to power transmission and distribution system.
Non-Sealed H-Grade Insulated Three Phase Dry Type Transformer
H class insulation non-sealed windings dry type transformers, which are made of NOMEX insulated materials certificated by UL in USA. Model 3: Sgb10-2500/10; Specification: SGS; HS Code: 850431900.
35kv Class 3-Phase Cast Resin off Circuit Tap Dry Type Transformer
Rated capacity: 20MVA; Rated voltage and tapping range: 35± 3x2.5%/10.5kV; Rated frequency: 50Hz; Cooling method: AN.
33kv Resin Casted Multi-winding Three Phase Dry Type Transformer
Core: Core-type Transformer; Winding Type: Multi-winding Transformer; Specification: IEC/ANSI/IEEE. BS; HS Code: 8504220000.
SC(L)B-35 35kv Cast Resin Indoor Multi-winding Dry Type Transformer
We use advanced electric, magnetic, thermal and mechanical computing software to calculate electro-magnetic field and magnetic flux leakage distributions, to analyzewave processes, and to select reliable insulation margin, thus to guarantee product reliability. Shape of Core: EC; Trademark: JSB; Origin: China.
Ohsas18001-2007 10kv Cast-Resin Two-winding Dry-Type Transformer
The dry type transformer is a transformer with an iron core and winding not immersed in the insulating liquid. Frequency Characteristics: Power Frequency; Brand: Zhebian; Origin: China.
Scb10 11 15 Three-Phase Epoxy Casting Resin Upgrading Dry-Type Transformer
10 KV grade SCB10, SCB11, SCBH15 epoxy casting dry-type transformers, can be used as upgrading products of oil-immersed distribution transformers.It has the most optimal performance in all kinds of dry-type transformer products. Shape of Core: Ring; Trademark: GSE; Origin: Shandong China.
Fujoe SG-0.75KVA Single phase Two-winding Dry Type Transformer
Installed in Factory, CNC Machine, Medical Equipment Isolation , Machine Tool, Printing Machine . Model NO.: SG-0.75KVA; Phase: Three; Cooling Method: Dry-type Transformer.
Sg-0.15kvasg Series Two-winding Wooden Box Dry Type Transformer
Installed in Factory, CNC Machine, Medical Equipment Isolation , Machine Tool, Printing Machine . Model NO.: SG SBK-0.15KVA; Phase: Three; Cooling Method: Dry-type Transformer.
Scb High Voltage Dry Type Energy Saving Dry Type Transformer
The product has been widely used in places such as power transmission and transformation system, commercial street, sport stadium, petrochemical enterprise, metro, railway station, airport and etc. Shape of Core: U; Trademark: FUJOE; Origin: Wenzhou.
Zenele Epoxy Cast Resin on-Load Tap Changer Dry-Type Transformer
Phase: Three; Cooling Method: Dry-type Transformer; Certification: ISO9001-2000, ISO9001, CCC; Frequency Characteristics: Power Frequency.
SCB10 Three-Phase High Voltage Cast Resin Dry-Type Transformer
Application: for power distribution system and large industrial enterprises, etc. Cooling Method: Dry-type Transformer; Certification: ISO9001-2000, ISO9001, CCC; Frequency Characteristics: Power Frequency.
33kv Air-Cooled Core-type Cast Resin Dry Type Distribution Transformer
Phase: Three; Cooling Method: Dry-type Transformer; Certification: ISO9001-2000, UL, ISO9001, CCC; Frequency Characteristics: Power Frequency.
SC10 11kv Energy-Saving Oil-immersed Dry Type Transformer
Phase: Three Cooling Method: Oil-immersed Type Transformer Certification: ISO9001-2000, UL, ISO9001, CCC Frequency Characteristics: Power Frequency
35kv Class Ovdt High Frequency Dry Type Distribution Transformer
The SGH(B) series non-encapsulated H-class dry-type transformer from Pearl Electric is the transformer featuring low noise, low partial discharge and low loss. Rated LV: 0.4kv Insulation Level: H. V Li/AC 75/35 L. V Li/AC 0/3 Origin: China
33kv Class 30kVA-10mva Core-type Cast-Resin Dry Type Transformer
As the professional power transformer manufacturer, Pearl Electric design and manufacture various types of dry-type power transformer. Insulation Level: H. V.: Li/AC 170/70 L. V.: 0/3; Trademark: PEARL ElECTRIC(PE); Origin: China
11~35kv Three Phase Cast Resin Step Down Dry Type Transformer
1.Various special requirement from customer or typical specification . 2.Competitive price (Real factory ). 3.Excellent quality control. 4.Good service and after sales.
IEC60076 Standard 10KV SC10 series Araldite Dry Type Transformer
IEC60076 Standard 10KV SC10 series Araldite Dry Type Transformer Features: Low loss, Low noise, No leakage, Easy installation, Maintenance free
Three phase energy saving cheap isolation dry type transformer
Use advanced technology, high mechanical strength, anti short circuit ability, small partial discharge, good thermal stability, high reliability, long service life. Model Number: SCB10/SCB11 Usage: Power Phase: Three
SCB Series IEC Standards 30KVA--2500KVA Dry type transformer
The core selects high quality cold rolled grain oriented silicon steel sheet. 45oC inclined seam. Five steps to fold the iron. Core column and iron yoke are multistage circular cross section shape. So that the transformer can get lower no-load loss and noise.
SCB10 500 kva 6kv epoxy resin cast dry-type power transformers
It is suitable for the places like government offices and bureau residential area and other areas that strictlydemand of special require for fire proof. Model Number: SCB10 Usage: Power Phase: Three
CE Approved Single/Three oil dehydration plant Dry Type transformer
Dry-type power transformers can be used in places like government offices and bureau residential area and other areas that strictlydemand of special require for fire proof. Model Number: SCB10 Usage: Power Phase: Three
SCB10 100KVA 11KV with temperature control system Dry type transformer
Place of Origin: Zhejiang, China (Mainland) Brand Name: jsm Model Number: SCB10 Usage: Power
10kv SG10 series H-grade insulation dry-type power transformer
Standards: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726. Model Number: SGB10 Usage: Power Phase: Three
SCB13-2383 three phase low loss noise power distribution transformer
T-Young produced the Amorphous alloy transformer with new magnetic material , the core part are made by amorphous alloy. Usage: Power Phase: Three Coil Structure: Toroidal
SC(B)10 Series IEC Standard Resin-insulated Dry Type Transformer
●Flame retardant, non-pollution, it can be installed directly in the load center. ●Maintenance-free, easy to be installed, low operating costs. Certificate: ISO9001 Application: Power Rated Voltage: 20kV
SG (B) 10 series Non-encapsulated H-class Dry-type Transformers
SG (B) 10 series of non-encapsulated H-class dry-type power transformers adopt the special process technology of German (MORA) dry-type transformers to ensure that the products fully meet the requirements such as fire prevention, waterproof ,environmental protection.
10kv SG10 series H-grade insulation dry-type power transformer
SG(B) type distribution transformer is suitable for the using in the adverse circumstances of high requirement for fire protection, high degree of load fluctuation and dirty, moist. Cooling Method: AN or AF Insulation Class: Grade H
10kv SG10 series H-grade insulation dry-type power transformer
SG(B) type distribution transformer is suitable for the using in the adverse circumstances of high requirement for fire protection, high degree of load fluctuation and dirty, moist. Dtandards: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726 Capacity Range: 80-2500kVA
10kv SC(B)10 series resin insulation dry-type power transformer
High voltage coils are wrapped with Polyester enameled wires, filled with glass fiber, and then resin under vacuum condition. 1. Dtandards: GB1094-1996; JB/T10088-2004; GB/T10228-2008; EQV IEC726 2. Voltage Grade: 6, 11kV
SCB10 33KV 35KV copper winding three phase dry type transformer
Core material: CRGO Silicon Steel Core winding material: Copper winding or Aluminium Certification: KEMA type test report 63MVA/110KV power transformer Standard: IEC, ANCI, DIN, BS or GB or by customer
SCB11 50Hz/60Hz 3 phases dry type distribution electrical transformer
All kinds of Dry-type Transformers, especially applicable for Power plant, High-rise Building, Business Center, Vessel, Port, Station Airport, Petrochemical Plant Railway, Tunnel, Mine Underground,. Usage: Electronic Phase: Three Coil Structure: Toroidal
6.6-35kv dry type 3 phases distribution electrical transformer
SG (B) H class dry type transformers is use of DuPont NOMEX paper based insulation system, during the entire life of the transformer remain extremely good electrical and mechanical properties. Model Number: SGB10 Usage: Electronic Phase: Three
SCB10 800KVA 10KV expoxy resin dry-type distributing transformer
10kV SCB10 Epoxy Resin Dry-type Power Distribution Transformer is used as a new generation product to replace the oil-immersed transformer. Level 11 means high performance. Model Number: SCB10-800/10 Usage: Power Phase: Three
SG10 6~10kV three phase H grade insulation dry-Type Transformer
The non-encapsulated coil three-phase dry type power transformer that adopt UL certif-icated NOMEX insulation system, with advantages of safe, reliable, energr saving, fireproof,explosion resistant, simple main-taining and so on.
SC(B)H15 10kV saving energy amorphous core dry-type transformer
This product has the merit of low no-load loss, no oil, self bum-out if prohibition is encountered,humidity endurance, anti-crack, no maintenance etc.
SC(B)9 10kV Series three phase cast Resin Dry-Type Transformer
As the coil is cast in vacuum state, the air bubble produced in coil can be prevented efficiently, the local discharging value fully accords with relative national standard.
SC(B)-200KVA/6kv 200KVA 6kv two windings dry type transformer
Professional solution: supply professional completed solution base on your technical requirements, to complete your technical plan. Insulaion level: F Vector group: Dyn11 or Yyn0 Tap range: ±5% or ±2*2.5%
Dyn11 or Yyn0 600KVA 10kv three phase dry type transformer
Professional solution: supply professional completed solution base on your technical requirements, to complete your technical plan. Usage: Power Phase: Three Coil Structure: Toroidal
1800kva 20kv on-load oil immersed power distribution transformer
oil immersed power distribution transformer 1. IEC, ANSI, BS 2. CE, ISO, CTQC, SGS 3. advanced performance, low price
AN/AF 12000KVA two windings three phase dry type transformer
Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . Phase: Three Coil Structure: Toroidal Coil Number: 2 windings
SC(B) Three Phase Toroidal Cast resin Dry type Transformer
Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . Model Number: SC(B)10-200 Usage: Power Phase: Three
SG(B)10-10kV 9kV H-class copper winding Dry type Transformer
Dry type transformer has following insulation classes: class B, class F, class H, class C, etc. Rated power range: 30-2500kVA High voltage range: 6-11kV Connection Symbol: Yyn0 Dyn11
50-2500kVA 20kV three phase cast expoy resin dry-type Transformer
SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically . Brand Name: APPERIN Model Number: SC(B)-25kV Usage: Power
50/60HZ three phase Non-encapsulated H class dry-type transformers
In general, it is typical of SG (B) 10-type H-class insulating dry-type power transformer to withstand strong thermal shock and bear enormous overload capacity. Coil Structure: Toroidal Coil Number: insulation Color: Customized Frequency: 50/60HZ
SG (B) 10H three phase Insulating Dry-type Power Transformer
In general, it is typical of SG (B) 10-type H-class insulating dry-type power transformer to withstand strong thermal shock and bear enormous overload capacity. Model Number: SG (B) 10H Usage: Power Phase: Three
SCB11 F or H Class three phase Dry-type Power Transformers
Low Loss: Its no-load loss is more than 20% lower than the SCB11 series products. Besides, it is energy-saving, economical as well as maintenance-free. Model Number: SCB11 Usage: Power Phase: Three
Three Phases Epoxy Resin Electrical Dry Type Power Transformer
Guangdong Sihui instrument current transformers are widely used in commercial, industrial and residential areas. Usage: Power Phase: Three Coil Structure: Toroidal, Toroidal
IECstandard 50/60Hz three phase Cast Resin Dry type Transformer
Vacuum cast coil dry-type transformers are moisture-proof, suitable for operation in very humid or heavily polluted environments. Coil Number: Other Rated capacity: Up to 30 MVA Input voltage: up to 52kv
SCB10 IEC Standard 30-16000kva single phase dry type transformer
The altitude is supposed to be lower than 1000m, the ambient temperature is lower than 40centigrade, the corresponding rating regulation is suggested to be done according to standard provided beyond above operation condition. Model Number: SCB10 Usage: Power Phase: Single
SCB10 IEC60076 three phase Ventilated dry-type transformers
The altitude is supposed to be lower than 1000m, the ambient temperature is lower than 40centigrade. Model Number: SCB10 Usage: Power Phase: Three
China supplier ISO & CE 50/60Hz 3 Phase Dry Type Isolating Transformer
SG Three Phase Dry Type Isolating Transformer is we reference to the international products. Model Number: SG, SG Usage: Electronic Phase: Three
SCB10 IEC60076 Standard LOW VOLTAGE DRY TYPE TRANSFORMER
Three phase dry type high voltage power transformer adopts high quality material and advanced technology. Color: Red Current Type: AC Frequency: 50Hz/60Hz
50/60Hz 380V~550V DG single phase dry type control transformer
DG single phase dry type control transformer is suitable for circuit of 50~60Hz. Model Number: DG Usage: Power Phase: Single Coil Structure: Toroidal
RoHs CE ISO9001 50Hz/60Hz Three Phase Dry Type Transformer
Using high quality materials and advanced technology professional production of 100 VA to 800 KVA. Model Number: SG Usage: Power Phase: Three
HSLEC 5000w 220v 110v step up step down dry type transformer
TC type step up and down transformer is specially designed for such electronic equipment whose rated AC voltage different from that of the local Voltage. Model Number: ST Usage: Power Phase: Single
HSLEC 110v 220v Single phase small electrical dry type transformer
HSLEC 110v 220v Single phase small electrical dry type transformer can be used in Computers, Duplication, ILLumination system, Medical instrument Refrigerator,Safety warning equipment. Model Number: ST Usage: Power Phase: Single
HSLEC SC(B)9 600v 400v three phase Dry Type Transformers
dry type transformer is widely used in the places such as hotel, restaurant, airport, power plant, hospital, skyscraper. Usage: Power Phase: Three Coil Structure: Toroidal
ISO9001:2008 2500kva wound core dry type transformer
Three-dimensional wound core dry type transformer has all the advantages of the normal H-class dry type transformer. Phase: Three Coil Structure: Toroidal Coil Number: Autotransformer
50/60Hz IEC Standards open dry type voltage step down transformer
Yhe winding adopts vacuum pressure impregnation(VPI), OVDT (open ventilated dry transformer) structure. Usage: power grid system Phase: Three Coil Structure: Toroidal
SCBH15 Amorphons metal dry type transformer with no oil
The dry-type transformer is without oil, so it is no danger of burning and can be installed indoor as well as be entered into load center to meet the needs of high-density load development in modern metropolises.
SCB10 10KV Epoxy resin dry type power transformer
SCB10 series transformers are poured in vacuum condition by using enhanced fiberglass thin insulation resin, and it becomes a strong and solid wholesome piece when drying up. Usage: Power Phase: Three Coil Structure: Toroidal
SCB10 epoxy resin cast dry-type transformer
The product has the advantages of high reliability, long life characteristics. According to the different use of the environment, can be configured with different degrees of protection of housing or housing notconfigured.
Factory Sale 30KVA Three Phase Dry-type Transformer
This series of transformer adopts advanced technology and strict desigh, with practical and latemodel structure with advantages of excellent performance, reliable operation, wide application, etc. Furthermore.
Epoxy resin dry-type power transformer
The SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically. The core is made of high-permeable grain-orientated silicon sheet and cast with imported epoxy resin.
- 1
- 2
- 3
- 4
- 5
SNC-Lavalin and ABB form new Joint Venture