Quick Details
Place of Origin: Shanghai, China (Mainland)
Brand Name: WEIHONG
Model Number: PM85A
Pulse Frequency: 160kHZ
Position Signal Type: Pulse + Direction
Control Signal Type: Differential signal
Control Card: PCI Slot Power
I/O Terminal Board: Standard 24V DC
Mating I/O Card: PCIMC-75AS
Packaging & Delivery
|
Packaging Details:
|
Standard package; Paper Box
|
|
Delivery Detail:
|
1-2 days after payment
|
WEIHONG CNC Control for 4 AXIS Milling/Engraving/Waterjet Machine-PM85A
Product Uses
PM85A, communication card, when used with NcStudio motion control software, has proven itself on routers, engraving and milling machines, drilling machines and cutting machines, available of comprehensive functions and convenient to use.
.jpg)
Configuration as follows:
One communication card PM85A ;
One Lambda 4S/5S series controller;
One NcStudio motion control software CD (Not required if software customized);
One DB9M/F cable (Cable length customizable);
NcStudio Software.
The system indicator lamp of PM85A is SYS OK, while that of Lambda 4S/5S series is SYSTEM. Their flash frequency is used to tell whether the system communication is normal, as follows:
Whenphysical connection is interrupted, the system indicator lamp flashes by being on for 0.5s and off for 0.5s sequentially.
When physical connection is normal, but dada connection interrupted, for example, there is no logical data or data upload is blocked, the system indicator lamp flashes slowly by being on for 1.5s and off for 1.5s sequentially.
When physical connection and data connection are both normal, the system indicator lamp flashes by being on for 0.25s and off for 0.25s sequentially.
When system exception occurs, like CRC check error, pulses full, and hardware encryption error, the system indicator lamp flashes by being on for 0.05s and off for 0.05s sequentially.
When hardware exception occurs, such as under voltage, hardware damage, pseudo soldering, and short circuit, the system indicator lamp is always on or off.
For a Lambda 4S/5S series CNC system, when PC logical data or physical connection interrupted, the IO ports on the controller and the extended terminal board maintain their status.