Performance Features
1.Automated calibration of transducer Zero Offset and/or Velocity ;
2.Automated gain、Peak Hold and Peak Memory;
3.Automated display precise flaw location(Depth d、level p、distance s、amplitude、sz dB、ф);
4.Automated switch three staff gauge ((Depth d、level p、distance s);
100 independence setup, any criterion can be input freely, we can work in the scene without test block;
5.Big memory of 300 A graph.
6.Gate and DAC alarm;Acoustic-Optical alarm;
7.RS232/USB port,communication with pc is easy;
8.The embeded software can be online updated;
9.Li battery, continue working time up to 10 hours;
10.Display freeze;
11.Automated echo degree;
12.Angles and K-value;
13.Lock and unlock function of system parameters;
14.Electronic clock calendar ;
15.Two gates setting and alarm indication;
16.High-speed capture and very low noise;
17.DAC、AVG ; Solid metal housing;
18.Automated calculate the size of the flaw with w ide bottom type in AVG function.
19.AWS D1.1;
20.6dB DAC functions;
21.Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;
22.Powerful pc software and reports can be export to excel;
Measuring Range and Measuring Error
Range of scanning: 0 mm ~6000 mm
Resolution for scanning: 0.1mm (2.5mm ~100mm) 1mm (100 mm ~6000mm)
Range of gain: 0dB ~110 dB
D-Delay: -20µs~+3400µs
P-Delay: 0µs~99.99µs
Sound speed: 1000 m/s~15000m/s
Operation Environment
Temperature: -10℃~50℃
Humidity: 20%~90%RH
Free of strong magnetic field and corrosion.
Power supply
Li battery 7.4V 4800mAh
Overall Dimension and Weight
Overall dimension: 240mm×150mm×50mm
Weight: 1.6kg
KAIRDA KUT500 Ultrasonic Flaw Detector
Technical Parameters
| Designation |
Technical Data |
| Range of scanning (mm) |
Range of scanning (mm):0~6000
Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000
Adjusting step: 0.1mm(2.5 mm~99.9mm),1mm(100mm~6000mm) |
| D-delay (ms) |
D-delay (ms):-20~+3400
Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,
700,800,900,1000,1500,2000,2500,3000,3400.
Adjusting steps: 0.1(-20ms~999.9ms),1(1000ms~3400ms) |
| P-delay (ms) |
P-delay:0.0~99.99
Adjusting steps: 0.01 |
| MTLVEL(m/s) |
MTLVEL:1000~15000
7 fixed levels: 2260,2730,3080,3230,4700,5920,6300,12000
Adjusting steps: 1 |
| Working mode |
Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe) |
| Frequency Range (MHz) |
0.5~20 |
| Gain adjustment (dB) |
0~110
Adjusting step: 0.0,0.1,0.5,1,2,6,12 |
| Reject |
0%~80% of screen height, step: 1% |
| Vertical linear error |
Vertical linear error is not more than 3% |
| Horizontal linear error |
Not more than 0.2% in the scanning range |
| Sensitivity Leavings |
≥62 dB |
| Dynamic range |
≥34dB |
| Alarm |
Three modes, i.e. forbidden wave, loss wave and auto |
| A-Scan display area |
Full screen or local
A-Scan display freezing and de-freezing A-Scan filling |
| Data save |
300 A-Scan images (including setting of instrument)
|
| Standard communication interface with PC |
RS232/USB |
| Measuring unit |
mm/inch |
| Battery |
Li battery 7.4V 4800mAh |
| Power adaptor |
Input 100V~240V/50Hz~60Hz
Output 9VDC/1.5A |
| Working temperature |
-10℃~50℃ |
| Working humidity |
20%~90% |
| Port type |
C9 |
| Overall dimension (mm) |
240×150×50 |
| Weight (kg) |
1.6 |