Quick Details
Description
Multiple functions integrated in one device, voltage. current .resistance .
thermocouple temperature .RTD, and also the capability to measure
and output functions
For industrial automation and control, laboratory and other environmental design,
production and maintenance.
Easy operation interface, the keyboard input.。
Wide viewing angle LCD display with backlight
Memory and recall 10 group setting
Scan mode/ Program mode
Remote control, Software support
.png)
Specification:
Input Voltage 30.000V/300.00mV
| |
Range |
Resolution |
Accuracy |
| 30.000V |
0~30.000V |
1mV |
0.02%+3 |
| 300.00Mv |
-10~300.00mV |
10uV |
0.015%+3 |
Current 30.000mA
| |
Range |
Resolution |
Accuracy |
| 30.000mA |
0~30.000mA |
1uV |
0.015%+3 |
Resistance 500.00/5.0000k Ω
| |
Range |
Resolution |
Accuracy |
| 500.00Ω |
0.00~500.00 |
10mΩ |
0.02%+10 |
| 5.0000KΩ |
0.0000~5.0000 |
100mΩ |
0.015%+10 |
Thermocouple temperature T J E K S R B N -200~1800 degC
Resolution 0.1
| Thermocouple |
Source range |
Setting resolution |
| T(CC) |
-200.0℃ to +400.0℃ |
0.1℃ |
| J(IC) |
-200.0℃ to +1200.0℃ |
0.1℃ |
| E(CRC) |
-200.0℃ to +1000.0℃ |
0.1℃ |
| K(CA) |
-200.0℃ to +1372.0℃ |
0.1℃ |
| S(PR10) |
-10.0℃ to +1768.0℃ |
0.1℃ |
| R(PR13) |
-10.0℃ to +1768.0℃ |
0.1℃ |
| B(PR30) |
+330.0℃ to +1820.0℃ |
0.1℃ |
| N |
-200.0℃ to +1300.0℃ |
0.1℃ |
RTD PT100 PT1000 PT500 (385/392) Cu50 Cu10 Ni120
| |
Range |
Resolution |
Accuracy |
| PT100 |
-200.0~800.0℃ |
0.1℃ |
0.5℃ |
| PT1000 |
-200.0~630.0℃ |
0.1℃ |
0.3℃ |
| PT500 |
-200.0~630.0℃ |
0.1℃ |
0.4℃ |
| Cu10 |
-100.0~260.0℃ |
0.1℃ |
1.8℃ |
| Cu50 |
-50.0~150.0℃ |
0.1℃ |
0.7℃ |
| Ni120 |
-20.0~260.0℃ |
0.1℃ |
0.4℃ |
Output voltage 20.000V/100.00Mv
| |
Range |
Resolution |
Accuracy |
| 20.000V |
0~20.000V |
1mV |
0.02%+3 |
| 100.00Mv |
-10~100.00mV |
10uV |
0.015%+3 |
current 24.000Ma、 4~20mA%
| |
Range |
Resolution |
Accuracy |
| 24.000mA |
0~24.000mA |
1uV |
0.015%+3 |
resistance 500.00/5.0000k OHM
| |
Range |
Resolution |
Accuracy |
| 500.00Ω |
0.00~500.00 |
10mΩ |
0.02%+10 |
| 5.0000KΩ |
0.0000~5.0000 |
100mΩ |
0.015%+10 |
thermocouple T J E K S R B N -200~1800 degC
Resolution 0.1
| Thermocouple |
Source range |
Setting resolution |
| T(CC) |
-200.0℃ to +400.0℃ |
0.1℃ |
| J(IC) |
-200.0℃ to +1200.0℃ |
0.1℃ |
| E(CRC) |
-200.0℃ to +1000.0℃ |
0.1℃ |
| K(CA) |
-200.0℃ to +1372.0℃ |
0.1℃ |
| S(PR10) |
-10.0℃ to +1768.0℃ |
0.1℃ |
| R(PR13) |
-10.0℃ to +1768.0℃ |
0.1℃ |
| B(PR30) |
+330.0℃ to +1820.0℃ |
0.1℃ |
| N |
-200.0℃ to +1300.0℃ |
0.1℃ |
RTD PT100 PT1000 PT500 385/392 Cu50 Cu10 Ni120
| |
Range |
Resolution |
Accuracy |
| PT100 |
-200.0~800.0℃ |
0.1℃ |
0.5℃ |
| PT1000 |
-200.0~630.0℃ |
0.1℃ |
0.3℃ |
| PT500 |
-200.0~630.0℃ |
0.1℃ |
0.4℃ |
| Cu10 |
-100.0~260.0℃ |
0.1℃ |
1.8℃ |
| Cu50 |
-50.0~150.0℃ |
0.1℃ |
0.7℃ |
| Ni120 |
-20.0~260.0℃ |
0.1℃ |
0.4℃
|
SHANGHAI YIHUA V&A INSTRUMENT CO.,LTD, known as Mastech Shanghai, is one of the major test instrument manufacturers in China specialized in professional test and measurement instruments .
As a high-tech equipped modern factory, we have advanced equipments in manufacturing and calibration.The quality assurance system and our well experienced R&D team make us one of the best quality factory in Asia. Our V&A brand gets known to be the first choice among professionals. Our product line covers different industries such as electronic tools, electrical power, food and chemical, atmosphere monitoring, education and consumer electronics, etc. With our strong tech support and marketing service, we are the main supplier of test instrument for the major distributors in over 100 countries.
As a comprehensive company,SHANGHAI YIHUA V&A INSTRUMENT CO.,LTD will do more to contribute to China's compatibility in the world market and will take the lead of the test instrument industry in China.