• 20kV current transformer using in generator

20kV current transformer using in generator

Generator CT can be divided into epoxy resin casting type and bushing type based on insulation method. And it can be divided into open-vertically installed type, sealed-busbar installed type and generator bushing installed type based on installation type.

Product Details

Quick Details

Description

Quick Details

  • Place of Origin: Liaoning, China (Mainland)
  • Brand Name: DYH
  • Model Number: LMZD-20B
  • Insulated Structure: Epoxy resin casting type/bushing type
  • Voltage Class: 20kV
  • Main material: Copper,epoxy resin
  • Supplier Location: Dalian,China
  • Category: Power distribution, equipment
  • Business Type: Manufacturer
  • Min. Order: One piece under discussion
  • Usage: Used in Generator and Enclosed Busbar
  • Installation Site: Indoor
  • Phase: Single

Packaging & Delivery

Packaging Details Export standard packages: 
1. General products: The goods are packed by plywood wooden cases 
2. With protection material inside for all the packages, e.g. EPE, Cystosepiment, Plastic film, Corner-wrapping and so on. 
3. Enhanced package for small order. 
4. We can do the marks as per the different requirements of the customers.
Delivery Time about 18-23 workdays after receiving the purchase order

Specifications

 

1. Rated Primary Current(A):6000-10000,12000 
2. Rated Insulation Leve(kV)l: 23/65/125 
3. Insulated Structure: Busbar Type 

 

LMZD-20B CURRENT TRANSFORMER

 

1. Rated Primary Current:6000-10000,12000A
2. Rated Insulation Level: 23/65/125KV
3. Insulated Structure: Busbar Type

 

1. General

Generator CT can be divided into epoxy resin casting type and bushing type based on insulation method. And it can be divided into open-vertically installed type, sealed-busbar installed type and generator bushing installed type based on installation type.

The large current CT, which is developed, manufactured by us and is used in generator, is with advanced technology and reliable quality. We adopt the special technology to eliminate the large current interference between the adjacent phases. We also make it realize the precision self-check function during the operation conditions.

Now we can make the largest current achieve 45000A and the large current CT can been applied to the 1000MW generator set.

2.  Research of generator CT in our factory

The characteristics of generator CT are great current, limiting installation space and complex magnetic field.

These characteristics have a great impaction on generator bushing installed CT. So to this kind of product good shielding measurement is very important. These characteristics have less impaction on vertical installed type and sealed-busbar installed type CT. For these two types of product casting quality and winding processing is most important.

We provide more than 240,000 pieces epoxy resin casting type instrument transformers which occupy 25% of total Chinese market. We are the first option for National big project and Switchgear Company. With more than 30 years experience, we set up a complete quality-insurance program and pass the ISO9001:2000 AND ISO14001:1996 standard.

Our generator CT conforms to GB1208,GB16847 and IEC60044-1 Standard. We passed the type test report of QITC, authentication of CHINA ELECTRIC COMPANY UNION and got advanced technology in the electric APPLIANCE UNION.

We try to control temperature rise and insulation between winding turns from every step, e.g. structure designing, raw material, producing process, quality insurance system.

In recent years, we have done a lot of research in generator bushing installed type CT. The maximum primary current of this kind CT can even reach 30000A. Because of limitation of actual test condition, usually can only do error test, influence test between phases and temperature rise test on CT using equal Ampere-turns method, i.e. the multiplying result of actual primary current and turns is equal to the rated-ampere-turns of CT and winding the primary conductor evenly around the circle. But actually, influence between phases can really affect the error and temperature rise of CT on the service site. In order to simulate this affection, we distribute the primary conductor winding in a certain angle around the circle and then do error test and temperature rise test. We decide the angle by simulate the 3 phases operation condition. Please refer to the 3 phases test circuit below. With good design and strict testing, our products have good performance in resisting affection between 3 phases and temperature rise. So many running reports from customers can certify our products qualification.

 

  1. T1----- Self voltage regulator 30KVA
  2. T2----- Large current transformer 30KVA
  3. CT---- To be tested TPY, 10P or 0.2S
  4. Busbar row 100*12. Outlet busbar is parallet to the backing. The distance between them is 2m.
  5. Phase distance between busbar is 1.2m.
  6. CT is vertical to busbar, busbar passes through the center of CT.

 

 3. Special performance of our product.

1)  The performance of measuring winding will not be affected by residual magnetism.

Normally,CT should be demagnetized before error test because of residual magnetism.All theory and test data certify :residual magnetism lower the accuracy class.Tested data in 500 kV grid net shows: 0.2 becaome 0.5 when in service.When large current especially short-circuit current and great DC component decaying time constant,there is greater residual magnetism. When in normal service, there is still residual magnetism. So the accrual accuracy class in service is much lower than the tested one. This leads to great loss and pollution in large capacity electric power plant.

If  required by our customers. DYH charge magnetism to CT. And the accuracy class remains the same before and after charging magnetism. This certifies the good accuracy class in service.

2)  Verify the error on service site by applying small secondary current

It is impossible to apply so large primary current on service.We can manufacture CTs being applied small secondary current to verify error on service site.

 

Please refer to the schematic diagram.When doing error test, we only apply maximum 6A current on secondary.It is not needed to connect primary conductor, increase primary current and using standard current transformer. So it is easier to test error on service site.

 

The two special performances above are achieved by using special CT and special shielding measurement .The cost is higher than normal but this method makes it easier to do error test periodically on service site.

Company Profile

Dalian No.1 instrument transformer Co., Ltd.,(DYH hereafter) former Dalian No.1 instrument transformer works, was founded in 1972, which is a Chinese leader in instrument transformer with more than 1500 employees and more than thirty years manufacturing history. The enterprise occupies an area of 150,000m2, the building area is 80,000m2. 

DYH's headquarter located in Dalian is the manufacture base of high voltage instrument transformer, medium voltage instrument transformer, insulated busbar, vacuum breaker and other power equipments. The sub-company and branch company located in Xiamen in China, Shanghai in China are mainly manufacturers and provide medium voltage series current and voltage transformers. 

With more than 180 engineers, the technical center in Dalian is responsible for MV and HV products, long term development and research of new products and new technique, and also provide technical support to all subcompanies and branch companies. 

The company has advanced epoxy resin vacuum casting production line, oil-immersed and SF6 gas insulated high voltage production line, epoxy immersed paper insulated busbar production line and silicone rubber composite material dry type wall bushing production line. Also the company has established medium and high voltage (instrument transformer, fully insulated busbar) insulation test lab, epoxy resin material and molding part physical-chemical test lab, oil and gas insulation test lab, which are all equipped with advanced domestic and foreign test equipments and have the ability of processing the test about corresponding material and technical research. The high voltage test lab is equipped with 1100kV power frequency test transformer and 3000kV impulse voltage generator, which has the ability of processing all type tests except rated dynamic and thermal current for 500kV and under 500kV instrument transformers. 

The major products include 0.5~500kV current and voltage transformer, 6~35kV vacuum breaker, 35kV and under 35kV power station used insulated busbar,110kV and under 110kV dry type wall bushing and other electrical equipments. 

The annual output of 6~35kV epoxy resin cast CT and PT is about three hundred thousand sets that occupies about 25% Chinese market. We are the first choice among domestic key projects and big switchgear companies. 

With novelty construction, advantage equipment and strong technical power, the 35~500kV oil-immersed and SF6 insulated instrument transformers are very competitive in domestic and oversea market. The annual output is over 1500 sets. 

With advanced technique and unique construction, the 35kV and under 35kV fully insulated busbar, 110kV and under 110kV dry type wall bushing are introduced from foreign advanced technique, which will have very wide market in near future. 

We establish a complete quality management assurance system about product development, manufacture and product market, and certified under ISO9001:2000, ISO14001:2004, OHSMS GB/T28001-2001 and others. 

Good faith, excellent quality, customer first are always DYH's utmost purpose and what DYH is making for.
Less
 

 

Post Buying Request

  • * Country:Please select country
  • * Title:Please input title
  • * Message:Please input message
  • Your message must be between 20-8000 characters
  • * Your Email Address:Please input Email
  • Your email is also your login ID